Description:
The 2240 basic device is the basis of our stationary gas measuring devices. The device is manufactured according to the customer's requirements for the gas to be monitored and measuring range. It has one gas channel as standard. Thanks to a simple proprietary machine interface, the unit can also be integrated into a higher-level automation system. A variety of options are available, such as data recording on a USB stick or sending the data to a cloud storage in combination with a protected web portal of ppm Messtechnik GmbH.
Features
- Stationary concentration monitor according to customer requirements
- Example of components and measuring ranges:
- Ammonia · 1-500 ppm · Resolution 0.1 ppm · Accuracy 2% of value ± 0.5 ppm
- C-Pentane · 5-500 mg/m³ · Resolution 0.3 mg/m³ · Accuracy 2% of value ± 1.6 mg/m³
- R11 · 5-500 mg/m³ · Resolution 0.6 mg/m³ · Accuracy 1% of value ± 3 mg/m³
- Tetrachlorethylene · 35-6000 mg/m³ · Resolution 0.7 mg/m³ · Accuracy 1% of value ± 3.7 mg/m³
- Sulfuryldifluoride · 0.5 – 100 ppm · Resolution 0.1 ppm · Accuracy 1% of value ± 0.5 ppm
- Readout in ppm and mg/m³
- Mass concentration normalized to 0°C and 1013mbar (other parameters possible)
- Hose length up to 100 metres (with 4mm inner diameter)
- Dimension: 23 x 27 x 15 cm, weight about 4.5 kg
- Power supply: 90-264 VAC / 47-63 Hz - max. 60 W
- Scope of delivery: instrument with power cable
- Recommended calibration interval 24 months
- MTBF >10.000h (at 10-40°C, gas filtration ≤5µm)
- Optional:
- GSM data transmission with cloud access
- Data storage on USB stick
- 2nd and 3rd measuring channel with selector switch
- Gas flow monitoring for blockage/failure
- High contrast electro-luminescence display
- Analogue data interface 4-20 mA or 0-10 V
- Transport case
> Operation Pictures > Manual > Contact Us > Our Distributors